PMD=DISABLED, B0ZONEBEN=DISABLED, LCD0HYS=ZERO, B1ZONEBEN=DISABLED, B0ZONEPEN=DISABLED, B0ZONECEN=DISABLED, P1ZONE=DISABLED, B1ZONEPEN=DISABLED, B1POL=PULSE_LOW, LCD1HYS=ZERO, BMD=MODE0, P0ZONE=DISABLED, C0ZONE=ZONEA, B1ZONEAEN=DISABLED, B1ZONECEN=DISABLED, C1ZONE=ZONEA, ACDEN=DISABLED, B0ZONEAEN=DISABLED, ATRKEN=DISABLED, LCMD=MODE0, B0POL=PULSE_LOW
LC Mode
ATRKEN | Automatic Tracking Enable. 0 (DISABLED): Disable automatic tracking. 1 (ENABLED): Enable automatic tracking. A new MAX value of any size will increase both the MAX and MIN by 1, and a new MIN value of any size will decrease both the MAX and MIN by 1. |
ACDEN | Automatic Center Discriminator Enable. 0 (DISABLED): Disable automatic center discriminator mode. Firmware must set the CD0 and CD1 fields. 1 (ENABLED): Enable automatic center discriminator mode. Hardware will keep the CD0 and CD1 fields centered between MAX and MIN. |
LCD0HYS | LC Discriminator 0 Digital Hysterisis. 0 (ZERO): A high-to-low transition occurs if LCCOUNT0 is less than CD0. 1 (MINUS1): A high-to-low transition occurs if LCCOUNT0 is less than CD0 - 1. 2 (MINUS2): A high-to-low transition occurs if LCCOUNT0 is less than CD0 - 2. 3 (MINUS3): A high-to-low transition occurs if LCCOUNT0 is less than CD0 - 3. |
LCD1HYS | LC Discriminator 1 Digital Hysterisis. 0 (ZERO): A high-to-low transition occurs if LCCOUNT1 is less than CD1. 1 (MINUS1): A high-to-low transition occurs if LCCOUNT1 is less than CD1 - 1. 2 (MINUS2): A high-to-low transition occurs if LCCOUNT1 is less than CD1 - 2. 3 (MINUS3): A high-to-low transition occurs if LCCOUNT1 is less than CD1 - 3. |
C0ZONE | Counter 0 Active Zone Select. 0 (ZONEA): Select zone A as the active zone for counter 0 (LCIN0 input). 1 (ZONEB): Select zone B as the active zone for counter 0 (LCIN0 input). 2 (ZONEC): Select zone C as the active zone for counter 0 (LCIN0 input). 3 (ZONED): Select zone D as the active zone for counter 0 (LCIN0 input). |
C1ZONE | Counter 1 Active Zone Select. 0 (ZONEA): Select zone A as the active zone for counter 1 (LCIN1 input). 1 (ZONEB): Select zone B as the active zone for counter 1 (LCIN1 input). 2 (ZONEC): Select zone C as the active zone for counter 1 (LCIN1 input). 3 (ZONED): Select zone D as the active zone for counter 1 (LCIN1 input). |
P0ZONE | Pulse 0 Active Zone Select. 0 (DISABLED): Disable the pulse 0 output (LCPUL0). 1 (C_ONLY): Select zone C only as the active zone for the pulse 0 output (LCPUL0). 2 (A_ONLY): Select zone A only as the active zone for the pulse 0 output (LCPUL0). 3 (A_AND_C): Select zones A and C as the active zones for the pulse 0 output (LCPUL0). |
P1ZONE | Pulse 1 Active Zone Select. 0 (DISABLED): Disable the pulse 1 output (LCPUL1). 1 (C_ONLY): Select zone C only as the active zone for the pulse 1 output (LCPUL1). 2 (A_ONLY): Select zone A only as the active zone for the pulse 1 output (LCPUL1). 3 (A_AND_C): Select zones A and C as the active zones for the pulse 1 output (LCPUL1). |
PMD | LC Pulse Mode. 0 (DISABLED): Disable pulse mode. 1 (TOGGLE): Toggle at the start of zone A or zone C. 2 (PULSE_LOW): Set the pulse mode to idle high, pulse low. 3 (PULSE_HIGH): Set the pulse mode to idle low, pulse high. |
B0ZONECEN | Bias 0 Zone C Enable. 0 (DISABLED): Disable bias 0 during zone C. 1 (ENABLED): Enable bias 0 during zone C. |
B0ZONEBEN | Bias 0 Zone B Enable. 0 (DISABLED): Disable bias 0 during zone B. 1 (ENABLED): Enable bias 0 during zone B. |
B0ZONEAEN | Bias 0 Zone A Enable. 0 (DISABLED): Disable bias 0 during zone A. 1 (ENABLED): Enable bias 0 during zone A. |
B0ZONEPEN | Bias 0 Zone P Enable. 0 (DISABLED): Disable bias 0 during zone P. 1 (ENABLED): Enable bias 0 during zone P. |
B0POL | Bias 0 Polarity. 0 (PULSE_LOW): Set bias 0 to idle high, pulse low. 1 (PULSE_HIGH): Set bias 0 to idle low, pulse high. |
B1ZONECEN | Bias 1 Zone C Enable. 0 (DISABLED): Disable bias 1 during zone C. 1 (ENABLED): Enable bias 1 during zone C. |
B1ZONEBEN | Bias 1 Zone B Enable. 0 (DISABLED): Disable bias 1 during zone B. 1 (ENABLED): Enable bias 1 during zone B. |
B1ZONEAEN | Bias 1 Zone A Enable. 0 (DISABLED): Disable bias 1 during zone A. 1 (ENABLED): Enable bias 1 during zone A. |
B1ZONEPEN | Bias 1 Zone P Enable. 0 (DISABLED): Disable bias 1 during zone P. 1 (ENABLED): Enable bias 1 during zone P. |
B1POL | Bias 1 Polarity. 0 (PULSE_LOW): Set bias 1 to idle high, pulse low. 1 (PULSE_HIGH): Set bias 1 to idle low, pulse high. |
BMD | Bias Mode. 0 (MODE0): Disable the bias signals. 1 (MODE1): Use the bias signals externally only (LCBIAS0 and LCBIAS1 outputs). 2 (MODE2): Use the bias signals internally only. 3 (MODE3): Use the bias signals externally (LCBIAS0 and LCBIAS1 outputs) and internally. |
LCMD | LC Mode. 0 (MODE0): The LC pulse asserts throughout zone A or zone C with a single-ended comparator using the counter and discriminator. 1 (MODE1): The LC pulse asserts throughout zone A or zone C with differential comparators using the counter and discriminator. 2 (MODE2): The LC pulse asserts throughout zone A or zone C with a single-ended comparator sampling and holding at the end of the LC pulse. 3 (MODE3): The LC pulse asserts throughout zone A or zone C with differential comparators sampling and holding at the end of the LC pulse. 4 (MODE4): The LC pulse starts at the beginning of zone A or C and stops with the timer with a single-ended comparator using the counter and discriminator. 5 (MODE5): The LC pulse starts at the beginning of zone A or C and stops with the timer with differential comparators using the counter and discriminator. 6 (MODE6): The LC pulse starts at the beginning of zone A or C and stops with the timer with a single-ended comparator sampling and holding at the end of the LC pulse. 7 (MODE7): The LC pulse starts at the beginning of zone A or C and stops with the timer with differential comparators sampling and holding at the end of the LC pulse. 8 (MODE8): The LC pulse starts at beginning of zone A or C and stops with the rising edge of the external stop input (STOPx) with a single-ended comparator using the counter and discriminator. 9 (MODE9): The LC pulse starts at beginning of zone A or C and stops with the falling edge of the external stop input (STOPx) with single-ended comparators using the counter and discriminator. 10 (MODE10): The LC pulse starts at beginning of zone A or C and stops with the rising edge of the external stop input (STOPx) with a single-ended comparator sampling and holding at the end of the LC pulse. 11 (MODE11): The LC pulse starts at beginning of zone A or C and stops with the falling edge of the external stop input (STOPx) with single-ended comparators sampling and holding at the end of the LC pulse. 12 (MODE12): Do not generate a pulse with a single-ended comparator using the timer and discrimintor. 13 (MODE13): Do not generate a pulse with differential comparators using the timer and discrimintor. 14 (MODE14): Do not generate a pulse with a single-ended comparator sampling and holding at the end of the zone. 15 (MODE15): Do not genreate a pulse with differential comparators sampling and holding at the end of the zone. |